{"product_id":"vulkem-360nf-base-coat","title":"Vulkem 360NF Base Coat - Low VOC, water-cured, rapid setting urethane membrane","description":"\u003ch2 style=\"color: #1c4f8a; margin-top: 0;\"\u003eTremco Vulkem® 360NF Base Coat\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.08em; color: #333;\"\u003e\u003cstrong\u003eLow-VOC, Water-Cured, Rapid-Setting Urethane Waterproofing Membrane\u003c\/strong\u003e | Brand: Tremco\u003c\/p\u003e\n\u003cp style=\"font-size: 1.02em; color: #444;\"\u003eTremco Vulkem® 360NF is a single-component, moisture-curing, rapid-setting \u003ca href=\"\/fr\/collections\/waterproofing-products\" title=\"Waterproofing Products\"\u003eurethane membrane\u003c\/a\u003e formulated as the base coat in Tremco’s Vulkem \u003ca href=\"\/fr\/collections\/traffic-deck-coatings\" title=\"Traffic Deck Coatings\"\u003etraffic deck\u003c\/a\u003e waterproofing system. Its low-VOC, solvent-free formulation is designed for use in enclosed parkades and occupied structures with appropriate ventilation. Confirm suitability, system compatibility, coverage, and cure requirements against the current Tremco TDS, SDS, and project specification before use.\u003c\/p\u003e\n\u003cdiv style=\"border-left: 4px solid #1C4F8A; background: #eef4fa; padding: 14px 18px; margin: 18px 0; border-radius: 4px;\"\u003e\n\u003cstrong style=\"color: #1c4f8a;\"\u003eProfessional system note:\u003c\/strong\u003e Vulkem 360NF is the \u003cstrong\u003ebase coat\u003c\/strong\u003e in the Vulkem traffic deck system. It must be applied over an approved Tremco primer and topcoated with Vulkem 951NF or another approved Tremco wearing course. \u003cstrong\u003eDo not use as a standalone waterproofing membrane.\u003c\/strong\u003e Confirm the full system specification before use.\u003c\/div\u003e\n\u003cdiv style=\"border: 1px dashed #1C4F8A; background: #f4f8fc; padding: 14px 18px; margin: 18px 0; border-radius: 6px;\"\u003e\n\u003cspan style=\"display:inline-block; font-size:0.75em; font-weight:700; letter-spacing:0.5px; color:#1C4F8A; text-transform:uppercase; margin-bottom:6px;\"\u003eAlso available — ResinTech alternative\u003c\/span\u003e\n\u003cp style=\"margin:0; color:#444;\"\u003ePrefer a locally stocked alternative? \u003ca href=\"\/fr\/products\/resintech-flexcoat-pu-polyurethane-waterproofing-membrane\" style=\"color:#1C4F8A; font-weight:600;\"\u003eResinTech FLEXCOAT-PU\u003c\/a\u003e is a single-component elastomeric polyurethane waterproofing \u0026amp; crack-bridging base membrane, stocked in North Vancouver and used in the same base-coat \/ traffic-deck waterproofing applications. Product chemistry and system build differ between manufacturers — confirm suitability against the current ResinTech TDS before substituting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eVulkem 360NF cures by reaction with atmospheric moisture to form a seamless, fully-adhered elastomeric membrane. Its NF (No Flash) designation indicates a low-VOC, non-flammable formulation — designed for enclosed parkades and occupied buildings where solvent-based products present ventilation and fire safety challenges; confirm ventilation requirements against the SDS.\u003c\/p\u003e\n\u003cp\u003eThe rapid-setting formulation is designed to reduce the time between base coat application and topcoat installation, helping to compress the overall project schedule; confirm cure times against the current TDS as they vary with temperature and humidity. Once cured, Vulkem 360NF is designed to provide a flexible, crack-bridging base that accommodates minor substrate movement and thermal cycling; confirm crack-bridging performance against the TDS and project specification.\u003c\/p\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003eKey Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-VOC, non-flammable (NF)\u003cbr\u003e\u003c\/strong\u003eFormulated for enclosed parkades and occupied structures with appropriate ventilation; confirm ventilation requirements against the SDS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid-Setting\u003cbr\u003e\u003c\/strong\u003eDesigned for faster cure than conventional urethane membranes; confirm cure times against the TDS as they vary with temperature and humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-component, moisture-curing\u003cbr\u003e\u003c\/strong\u003eNo mixing required; apply directly from the pail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless, fully-adhered membrane\u003cbr\u003e\u003c\/strong\u003eDesigned to eliminate laps and seams; final performance depends on substrate condition, preparation, and application method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrack-bridging elastomeric properties\u003cbr\u003e\u003c\/strong\u003eDesigned to accommodate minor substrate movement and thermal cycling; confirm crack-bridging performance against the TDS and project specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTremco system compatible\u003cbr\u003e\u003c\/strong\u003eDesigned for use with Vulkem 191 QD Primer and Vulkem 951NF topcoat as part of a complete traffic deck assembly; confirm system compatibility against the current Tremco specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBase coat membrane in Vulkem vehicular traffic deck waterproofing systems\u003c\/li\u003e\n\u003cli\u003eBase coat membrane in Vulkem pedestrian traffic deck waterproofing systems\u003c\/li\u003e\n\u003cli\u003eParkade and parking structure deck waterproofing\u003c\/li\u003e\n\u003cli\u003ePodium deck and plaza deck waterproofing base coat\u003c\/li\u003e\n\u003cli\u003eRamp and drive aisle waterproofing base coat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003ePerformance Highlights\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 8px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eef4fa;\"\u003e\n\u003ctd style=\"border: 1px solid #c9d6e5; padding: 10px;\"\u003e\n\u003cstrong\u003eChemistry\u003c\/strong\u003e\u003cbr\u003eSingle-component polyurethane (urethane)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #c9d6e5; padding: 10px;\"\u003e\n\u003cstrong\u003eCure Mechanism\u003c\/strong\u003e\u003cbr\u003eMoisture-curing, rapid-setting\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #c9d6e5; padding: 10px;\"\u003e\n\u003cstrong\u003eVOC\u003c\/strong\u003e\u003cbr\u003eLow-VOC, non-flammable (NF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eef4fa;\"\u003e\n\u003ctd style=\"border: 1px solid #c9d6e5; padding: 10px;\"\u003e\n\u003cstrong\u003eMembrane Type\u003c\/strong\u003e\u003cbr\u003eFluid-applied, fully-adhered base coat\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #c9d6e5; padding: 10px;\"\u003e\n\u003cstrong\u003eSystem Role\u003c\/strong\u003e\u003cbr\u003eBase coat \/ waterproofing layer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #c9d6e5; padding: 10px;\"\u003e\n\u003cstrong\u003eCompatible Topcoat\u003c\/strong\u003e\u003cbr\u003eVulkem 951NF (or approved equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003eSurface Preparation\u003c\/h2\u003e\n\u003cp\u003eConcrete must be structurally sound, clean, and free of laitance, oil, grease, curing compounds, and form release agents. Mechanically profile the surface to the CSP specified in the TDS. Fill surface voids, honeycombs, and bug holes with a compatible patching mortar. Apply Vulkem 191 QD Primer (or approved Tremco primer) at the specified coverage rate and allow to dry before applying Vulkem 360NF. Refer to the current Tremco system specification for full substrate preparation requirements.\u003c\/p\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003eApplication Instructions\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstrate preparation:\u003c\/strong\u003e Prepare the concrete as described above. Apply approved primer and allow it to dry to the tack-free state specified in the TDS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetail work:\u003c\/strong\u003e Apply membrane to all coves, inside and outside corners, pipe penetrations, and construction joints before field application. Embed reinforcing fabric at all details as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField application:\u003c\/strong\u003e Apply Vulkem 360NF by squeegee and back-roll at the wet film thickness specified in the TDS. Ensure uniform coverage with no holidays or thin spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCure:\u003c\/strong\u003e Allow to cure to the state specified in the TDS before applying the topcoat. Cure time is temperature and humidity dependent.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTopcoat:\u003c\/strong\u003e Apply Vulkem 951NF (or approved topcoat) within the recoat window specified in the TDS.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #1c4f8a;\"\u003eLimitations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMust be used as part of an approved Tremco Vulkem traffic deck system, not a standalone waterproofing membrane.\u003c\/li\u003e\n\u003cli\u003eDo not apply to substrates with active water leaks or running water.\u003c\/li\u003e\n\u003cli\u003eDo not apply below minimum temperature or when rain or condensation is expected before cure; confirm temperature requirements against the TDS.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the maximum recoat window without re-priming the surface.\u003c\/li\u003e\n\u003cli\u003ePot life and cure time are temperature and humidity-dependent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"border-left: 4px solid #1C4F8A; background: #eef4fa; padding: 12px 16px; margin: 16px 0; border-radius: 4px;\"\u003e\n\u003cstrong\u003ePurchasing Note:\u003c\/strong\u003e All sales are intended for professional and trade purchasers. Before ordering, confirm product suitability, quantity, system compatibility, substrate condition, pickup timing, and delivery requirements. Product use and installation are the responsibility of the purchaser and installer.\u003c\/div\u003e\n\u003chr\u003e\n\u003cp style=\"font-size: 0.9em; color: #555;\"\u003e\u003cstrong style=\"color: #1c4f8a;\"\u003eCanopus Supply Inc.\u003c\/strong\u003e — Authorized Tremco Distributor, Metro Vancouver \u0026amp; BC\u003c\/p\u003e\n\u003cp style=\"font-size: 0.85em; color: #777;\"\u003e\u003cem\u003eTechnical information is provided for professional reference only. Product selection, substrate preparation, installation method, coverage, cure time, system compatibility and final performance remain the responsibility of the purchaser, installer, project specifier and\/or manufacturer documentation. Always confirm suitability against the current TDS, SDS, project specification and site conditions before use.\u003c\/em\u003e\u003c\/p\u003e","brand":"Tremco","offers":[{"title":"Default Title","offer_id":40165483839667,"sku":"","price":480.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/9483\/8195\/files\/vulkem-360nf-base-coat-low-voc-water-cured-rapid-setting-urethane-membrane-7966327.png?v=1782292274","url":"https:\/\/www.canopussupply.com\/fr\/products\/vulkem-360nf-base-coat","provider":"Canopus Supply Inc","version":"1.0","type":"link"}